Attributes | Values |
---|
rdf:type
| |
rdfs:seeAlso
| |
Description
| - The bolometer-based imaging systems are very demanding devices and they have to be able to respond to extremely low amplitude of incoming heat energy. Numerous features are pushed near to perfection, such as IR absorption, thermal isolation, bolometer response time and read-out integrated circuit (ROIC). All of those parameters/components must be optimized as unit system. Due to the reason the project deals with utilization new materials with high IR absorption and techniques of their preparation compatible with IC fabrication. The issue of compatibility is really a challenge because for synthesis of nanostructures as for instance carbon nanotubes is necessary high temperature above 500°C. Micromembrane of bolometer covered with nanostructures with IR absorption higher than 0,97 and technology for its covering is project output. Behind of technology part the ROIC systems will be study to design circuitry for fast signal reading, their compensation and processing. The systems will be fabricated on the chip for testing with help of program Europractice. (en)
- Na bolometrech založené systémy snímání obrazu jsou velmi složitá zařízení, která musí zachytit extrémně nízké amplitudy přicházející tepelné energie. Řada vlastností je již dotažena téměř do dokonalosti jako absorpce IR, tepelná izolace, časová odezva bolometru a integrace obvodů pro čtení (ROIC). Všechny tyto parametry/komponenty musí být optimalizovány jako jeden společný systém. Z tohoto důvodu se projekt bude zabývat využitím nových materiálů s vysokou absorpcí infračerveného záření a technikami jejich přípravy tak, aby byla kompatibilní s výrobou integrovaných obvodů. Problematika kompatibility je obzvláště obtížná, protože pro syntézu nanočástic jako např. uhlíkových nanotrubic je zapotřebí vyšších teplot a to až nad 500°C. Výstupem bude mikromembrána bolometru pokrytá nanostrukturami s absorpcí IR záření větší než 0,97 a technologie pro její pokrytí. Vedle technologické části budou studovány nové ROIC systémy, které přinesou obvody pro rychlé čtení signálů, jejich kompenzaci a zpracování. Tyto systémy budou pro testování vyrobeny na čipu v rámci programu Europractice.
|
Title
| - New Nanostructured Sensing System for Infrared detection (NanoIR) (en)
- Nový nanostrukturovaný systém pro detekci infračerveného záření (NanoIR)
|
skos:notation
| |
http://linked.open...avai/cep/aktivita
| |
http://linked.open...kovaStatniPodpora
| |
http://linked.open...ep/celkoveNaklady
| |
http://linked.open...datumDodatniDoRIV
| |
http://linked.open...i/cep/druhSouteze
| |
http://linked.open...ep/duvernostUdaju
| |
http://linked.open.../cep/fazeProjektu
| |
http://linked.open...ai/cep/hlavniObor
| |
http://linked.open...vai/cep/kategorie
| |
http://linked.open.../cep/klicovaSlova
| - IR absoption, nanowires, nanotubes, bolemeter (en)
|
http://linked.open...ep/partnetrHlavni
| |
http://linked.open...inujicichPrijemcu
| |
http://linked.open...cep/pocetPrijemcu
| |
http://linked.open...ocetSpoluPrijemcu
| |
http://linked.open.../pocetVysledkuRIV
| |
http://linked.open...enychVysledkuVRIV
| |
http://linked.open...lneniVMinulemRoce
| |
http://linked.open.../prideleniPodpory
| |
http://linked.open...iciPoslednihoRoku
| |
http://linked.open...atUdajeProjZameru
| |
http://linked.open.../vavai/cep/soutez
| |
http://linked.open...usZobrazovaneFaze
| |
http://linked.open...ai/cep/typPojektu
| |
http://linked.open...ep/ukonceniReseni
| |
http://linked.open.../cep/vedlejsiObor
| |
http://linked.open...ep/zahajeniReseni
| |
http://linked.open...tniCyklusProjektu
| |
http://linked.open.../cep/klicoveSlovo
| - nanotubes
- nanowires
- IR absoption
|
is http://linked.open...vavai/cep/projekt
of | |