About: Quartz trap for ultratrace determination of lead and tin – optimization, detector comparison and mechanistic study     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The aim of this project is to optimize conditions for Sn and Pb preconcentration at quartz surface after hydride generation. Potential of coupling of the quartz trap to different spectrometric detectors, namely atomic absorption and fluorescence spectrometer and also inductively coupled plasma mass spectrometer will be tested. Simple analytical methods for ultratrace determination of Sn and Pb will be validated in the best arrangement from both analytical and economical points of view. Interference of other elements will be studied and reliability of the developed methods will be demonstrated using reference materials. Complex mechanistic study will be performed to investigate processes during analyte collection and volatilization. Understanding them will allow us to control and reduce interference. Radioactive indicators will be used to quantify trapping efficiency and visualize spatial distribution of analyte in the trap. Transmission electron microscopy and X-ray structure analysis will enable to characterize analyte forms during collection/volatilization and their particle size.  (en)
  • Projekt si klade za cíl optimalizovat podmínky prekoncentrace Sn a Pb na křemenném povrchu po generování jejich hydridů. Bude testováno spojení křemenného prekoncentračního zařízení s různými spektrometrickými detektory, jmenovitě atomovou absorpční a fluorescenční spektrometrií a hmotnostní spektrometrií s indukčně vázaným plazmatem. Pro uspořádání s nejvýhodnějšími analytickými i ekonomickými parametry budou validovány jednoduché analytické metody stanovení ultrastopových koncentrací Sn a Pb. Rovněž budou studovány interference dalších prvků na tato stanovení a použitelnost metod bude demonstrována na analýzách referenčních materiálů. Dalším cílem projektu je komplexní studie vedoucí k pochopení mechanismu dějů během prekoncentrace. Ke zjištění účinnosti prekoncentrace a prostorové distribuce analytu v prekoncentračním zařízení budou použity radioaktivní indikátory. Transmisní elektronová mikroskopie a rentgenová strukturní analýza umožní charakterizaci forem analytu i velikosti částic během záchytu a uvolnění analytu. Těchto poznatků bude využito při eliminaci interferencí.
Title
  • Quartz trap for ultratrace determination of lead and tin – optimization, detector comparison and mechanistic study (en)
  • Křemenné prekoncentrační zařízení pro stanovení ultrastopových koncentrací olova a cínu – optimalizace, porovnání detektorů a mechanistická studie
skos:notation
  • GPP206/11/P002
http://linked.open...avai/cep/aktivita
http://linked.open...kovaStatniPodpora
http://linked.open...ep/celkoveNaklady
http://linked.open...datumDodatniDoRIV
http://linked.open...i/cep/druhSouteze
http://linked.open...ep/duvernostUdaju
http://linked.open.../cep/fazeProjektu
http://linked.open...ai/cep/hlavniObor
http://linked.open...hodnoceniProjektu
http://linked.open...vai/cep/kategorie
http://linked.open.../cep/klicovaSlova
  • Hydride generation trapping quartz surface atomic absorption spectrometry inductively coupled plasma mass spectrometry method optimization mechanistic study tin lead (en)
http://linked.open...ep/partnetrHlavni
http://linked.open...inujicichPrijemcu
http://linked.open...cep/pocetPrijemcu
http://linked.open...ocetSpoluPrijemcu
http://linked.open.../pocetVysledkuRIV
http://linked.open...enychVysledkuVRIV
http://linked.open...lneniVMinulemRoce
http://linked.open.../prideleniPodpory
http://linked.open...iciPoslednihoRoku
http://linked.open...atUdajeProjZameru
http://linked.open.../vavai/cep/soutez
http://linked.open...usZobrazovaneFaze
http://linked.open...ai/cep/typPojektu
http://linked.open...ep/ukonceniReseni
http://linked.open...ep/zahajeniReseni
http://linked.open...jektu+dodavatelem
  • Cíle projektu, tedy optimalizace podmínek generování a prekoncentrování hydridů Pb a Sn a konstrukce SiO2 atomizátoru byly splněny. Zařízení pro ultrastopovou analýzu Pb a Sn bylo testováno s různými detektory, nejvhodnější byla detekce pomocí AAS. Dále byly studovány interference a mechanismy atomizace hydridů. Chybí větší důraz na reálné vzorky. Dosažené meze detekce jsou srovnatelné s ICP-MS. (cs)
  • The objectives of the project, i.e. optimization of hydride generation of Pb and Sn and SiO2 atomizer design, have been met. Equipment for ultra-trace analysis was tested with different detectors, AAS was chosen as the best. The interference and the mechanisms of atomization were studied too. A greater emphasis on real samples is missing. The achieved detection limits are comparable with ICP-MS. (en)
http://linked.open...tniCyklusProjektu
is http://linked.open...vavai/cep/projekt of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 39 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software