About: Electrochemical Biosensors Based on Enzymatic Reactor with Amalgam Powder     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Enzymatic reactor based on the powder of silver solid amalgam was suggested as the main part of biosensors in flow systems for the first time. 4-aminothiophenol, glutaraldehyde and enzyme were gradually bonded to the amalgam surface. Large surface of the fine amalgam particles maintains a big quantity of enzyme molecules. Biosensors were tested with enzymes ascorbate oxidase, glucose oxidase, catalase, tyrosinase and laccase. Electrochemical detection of the oxygen concentration change (for the first 3 enzymes) or the quinones concentration (tyrosinase and laccase) in the measured solution was done amperometrically by means of the tubular detector of silver solid amalgam. The current response of each biosensor was optimized with respect to the detection potential, the flow rate of the mobile phase, the injection volume and the enzymatic reactor volume. Under the found optimum conditions, concentration dependence and some statistical parameters of repeated measurements (relative standard deviation (RSD) for the studied enzymes was in the range 0.81 – 2.1 %) were measured. Biosensor with the ascorbate oxidase reactor was used for determination of ascorbic acid in the vitamin tablet Celaskon. Results of the analysis were in good agreement with the contents of ascorbic acid declared by manufacturer and the RSD of these analyses was 2.0 %.
  • Enzymatic reactor based on the powder of silver solid amalgam was suggested as the main part of biosensors in flow systems for the first time. 4-aminothiophenol, glutaraldehyde and enzyme were gradually bonded to the amalgam surface. Large surface of the fine amalgam particles maintains a big quantity of enzyme molecules. Biosensors were tested with enzymes ascorbate oxidase, glucose oxidase, catalase, tyrosinase and laccase. Electrochemical detection of the oxygen concentration change (for the first 3 enzymes) or the quinones concentration (tyrosinase and laccase) in the measured solution was done amperometrically by means of the tubular detector of silver solid amalgam. The current response of each biosensor was optimized with respect to the detection potential, the flow rate of the mobile phase, the injection volume and the enzymatic reactor volume. Under the found optimum conditions, concentration dependence and some statistical parameters of repeated measurements (relative standard deviation (RSD) for the studied enzymes was in the range 0.81 – 2.1 %) were measured. Biosensor with the ascorbate oxidase reactor was used for determination of ascorbic acid in the vitamin tablet Celaskon. Results of the analysis were in good agreement with the contents of ascorbic acid declared by manufacturer and the RSD of these analyses was 2.0 %. (en)
Title
  • Electrochemical Biosensors Based on Enzymatic Reactor with Amalgam Powder
  • Electrochemical Biosensors Based on Enzymatic Reactor with Amalgam Powder (en)
skos:prefLabel
  • Electrochemical Biosensors Based on Enzymatic Reactor with Amalgam Powder
  • Electrochemical Biosensors Based on Enzymatic Reactor with Amalgam Powder (en)
skos:notation
  • RIV/61388955:_____/14:00428759!RIV15-GA0-61388955
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GAP206/11/1638), P(GAP208/12/1645)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 14099
http://linked.open...ai/riv/idVysledku
  • RIV/61388955:_____/14:00428759
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Electrochemical biosensors; Flow analysis; Amperometry (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [6BDB2DE08F2F]
http://linked.open...v/mistoKonaniAkce
  • Jetřichovice
http://linked.open...i/riv/mistoVydani
  • Ústí nad Labem
http://linked.open...i/riv/nazevZdroje
  • Sborník přednášek mezinárodní odborné konference XXXIV. Moderní Elektrochemické Metody
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Barek, J.
  • Josypčuk, Bohdan
  • Josypčuk, Oksana
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Best Servis
https://schema.org/isbn
  • 978-80-905221-2-1
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 35 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software