About: Apparatus for automation of electrochromatographic and electrophoretic analysis     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Capillary electrochromatography (CEC), which is an extension of capillary electrochromatography (CE), experiences intensive progress in column technology and practical applications. Minor attention was devoted to the development of specialized instrumentation opening up all benefits of the method and enabling its automation. The main result of the planed project would be a crucial component of the automated electrophoreograph - integrated sample injector and mobile phase gradient generator. As a platform for its development will serve computerized liquid manipulator, invented in the Institute of Analytical Chemistry, Brno. The principle of this device make possible mixing and consecutive introduction of various liquids into a space under pressure. In the continuity on the previous research, further results in the field of monolithic column technology and lightguide-based optical detection methods are to be expected. (en)
  • Kapilární elektrochromatografie (CEC), která je dalším stupněm rozvoje kapilární elektroforézy (CE), prochází prudkým rozvojem kolonové technologie a aplikačních možností. Menší pozornost byla zatím věnována tvorbě specializované instrumentace, umožňující využití všech výhod metody a její automatizaci. Hlavním výsledkem předkládaného projektu bude rozhodující komponenta automatického elektrochromatografu - integrovaný dávkovač vzorku a generátor gradientu mobilní fáze. Jako platforma pro jeho vývoj bude sloužit výsledek základního výzkumu, realizovaný v Ústavu analytické chemie AV ČR - počítačem řízený kapalinový manipulátor. Jeho princip umožňuje programované míchání a postupné dávkování několika kapalin do prostoru se zvýšeným tlakem. V návaznosti na dosavadní výzkum lze očekávat i další výsledky projektu v oblasti technologie přípravy polymerních monolitických náplní a optických detekčních metod na bázi světlovodů. (cs)
Title
  • Apparatus for automation of electrochromatographic and electrophoretic analysis (en)
  • Zařízení pro automatizaci elektrochromatografické a elektroforetické analýzy (cs)
http://linked.open...avai/druh-souteze
http://linked.open...domain/vavai/faze
http://linked.open...vavai/hlavni-obor
http://linked.open...vavai/id-aktivity
http://linked.open.../vavai/id-souteze
http://linked.open...n/vavai/kategorie
http://linked.open...vai/klicova-slova
  • capillary electrochromatography;instrumentation;automation;mobile phase gradient;optical detection (en)
http://linked.open...nujicich-prijemcu
http://linked.open...avai/poskytovatel
http://linked.open...ai/statni-podpora
http://linked.open...vavai/typProjektu
http://linked.open...ai/uznane-naklady
http://linked.open...ai/pocet-prijemcu
http://linked.open...cet-spoluprijemcu
http://linked.open...ai/pocet-vysledku
http://linked.open...ku-zverejnovanych
is http://linked.open...ain/vavai/projekt of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 26 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software