About: Biomechanical Analysis of micromotions and loosening of cemented acetabular     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • "The proposed grant project is of interdisciplinary character and deals with the description of actual biomechanical behaviour of hip joint and the cemented acetabular cups: (i) Construction of 3D FE models of the pelvis with cemented acetabular cups. (ii) Finding of the causes of the development of the micromotions of cemented acetabular cups and analysis of their loosening that can originate during gait loading, because the leaked-out blood creates a mid-layer on the cement-bone interface and the abrasion particles of the polyethylene penetrate into the newly formed interspace and induce formation of osteoagressive granuloma and consecutive osteolysis. Later, the cemented acetabular cup loosening takes place. (ii) Assessment of the microdeformation of the polyethylene cup during the gait loading. (iii) Optimisation of the cement thickness and the diameter, depth and number of acetabular ""keyholes"" to be drilled into the pelvic bone to maximise the torque rigidity of acetabular cups." (en)
  • Grant je interdisciplinárního charakteru a patří do základního výzkumu. Na základě klinických poznatků z ortopedie se bude zabývat výpočtovým a experimentálním modelováním biomechanických procesů v kyčelním kloubu, příčin vzniku mikropohybů cementovaných acetabulárních implantátů a jejich uvolňováním při reálném zatěžování při lidské aktivitě. Pro analýzu budou vytvořeny konečněprvkové modely pánve s acetabulární jamkou na základě CT snímků. Bude posouzen vliv otěrové hmoty z polyetylénu na uvolňování jamky. Bude vypracována metoda pro optimalizaci způsobu ukotvení cementované kyčelní jamky. Dále je nutno vytvořit pomocí výpočtového modelování inženýrskou podporu ortopédům při operacích na kyčelním kloubu s různým stupněm postižení, aby byl dosažen vysoký stupeň pooperační spolehlivosti. Výsledkem řešení budou také kritéria po posouzení spolehlivosti cementované acetabulární jamky ve srovnání s necementovanou (mnohem dražší) pro jednotlivé operace. (cs)
Title
  • Biomechanická analýza mikropohybů a uvolnění cementovaných acetabulárních implantátů (cs)
  • Biomechanical Analysis of micromotions and loosening of cemented acetabular (en)
http://linked.open...vai/cislo-smlouvy
http://linked.open...avai/druh-souteze
http://linked.open...domain/vavai/faze
http://linked.open...vavai/hlavni-obor
http://linked.open...vai/vedlejsi-obor
http://linked.open...vavai/id-aktivity
http://linked.open.../vavai/id-souteze
http://linked.open...n/vavai/kategorie
http://linked.open...vai/klicova-slova
  • THR; acetabular implants; bone cement; micromotions; acetabular cup loosening; abrasion particles of the polyethylene; 3-D FE model of the pelvis; CT scans (en)
http://linked.open...avai/konec-reseni
http://linked.open...nujicich-prijemcu
http://linked.open...avai/poskytovatel
http://linked.open...avai/start-reseni
http://linked.open...ai/statni-podpora
http://linked.open...vavai/typProjektu
http://linked.open...ai/uznane-naklady
http://linked.open...ai/pocet-prijemcu
http://linked.open...cet-spoluprijemcu
http://linked.open...ai/pocet-vysledku
http://linked.open...ku-zverejnovanych
is http://linked.open...ain/vavai/projekt of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 107 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software