About: Analysis of the Accuracy of Fibre-optic Strain Gauges     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • In the last few years, the field of structure monitoring is increasingly utilizing systems based on fiber-optic technologies. The fiber-optic technology exhibit many advantages such as higher quality measurements, higher reliability, easier installation and maintenance, insensitivity to the environment (mainly to the electromagnetic field), corrosion resistance, safety in explosive and flammable environments, the possibility of long-term monitoring and lower cost per lifetime. The SOFO fibre-optic strain gauges were used to perform check measurements of the overall relative deformation of a real reinforced concrete structure. The long-term monitoring of the structure revealed that the measurement readings obtained from these fibre-optic strain gauges differed from each other. Therefore more attention was paid to the calibration of these fibre-optic strain gauges and to determining their measurement accuracy. The experimental results show that it is necessary to calibrate SOFO strain gauges before they are used, and their calibration constant determined.
  • In the last few years, the field of structure monitoring is increasingly utilizing systems based on fiber-optic technologies. The fiber-optic technology exhibit many advantages such as higher quality measurements, higher reliability, easier installation and maintenance, insensitivity to the environment (mainly to the electromagnetic field), corrosion resistance, safety in explosive and flammable environments, the possibility of long-term monitoring and lower cost per lifetime. The SOFO fibre-optic strain gauges were used to perform check measurements of the overall relative deformation of a real reinforced concrete structure. The long-term monitoring of the structure revealed that the measurement readings obtained from these fibre-optic strain gauges differed from each other. Therefore more attention was paid to the calibration of these fibre-optic strain gauges and to determining their measurement accuracy. The experimental results show that it is necessary to calibrate SOFO strain gauges before they are used, and their calibration constant determined. (en)
Title
  • Analysis of the Accuracy of Fibre-optic Strain Gauges
  • Analysis of the Accuracy of Fibre-optic Strain Gauges (en)
skos:prefLabel
  • Analysis of the Accuracy of Fibre-optic Strain Gauges
  • Analysis of the Accuracy of Fibre-optic Strain Gauges (en)
skos:notation
  • RIV/68407700:21610/13:00216077!RIV14-MPO-21610___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(FR-TI3/732)
http://linked.open...iv/cisloPeriodika
  • 6
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 60661
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21610/13:00216077
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Fibre-optic strain gauge; SOFO system; calibration; accuracy (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [9B992B3FF7A4]
http://linked.open...i/riv/nazevZdroje
  • Acta Polytechnica
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 53
http://linked.open...iv/tvurceVysledku
  • Vokáč, Miroslav
  • Jiroutová, Dita
issn
  • 1210-2709
number of pages
http://bibframe.org/vocab/doi
  • 10.14311/AP.2013.53.0872
http://localhost/t...ganizacniJednotka
  • 21610
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 22 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software