About: Apparatus for On-line Transparency Measurement of Scintillation Detector Materials in Gamma and Electron Radiation Fields     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The described apparatus provides excellent conditions for the study of scintillations properties in plastic and crystal scintillating detector materials in static and dynamic electron and gamma radiation fields using the light transparency measurement. The apparatus is consist of two main parts: an optical bench and a specially developed double beam spectrophotometer. The optical bench is installed at the accelerator output and serves for setting of investigated samples. The spectrophotometer, which is situated in a radiation protected room, is based on the 256-diode array spectrometer with optical fiber input LASP 2; the spectral range from 350 to 735 nm is analyzed simultaneously. All the apparatus parts are controlled by PC from a radiation protected operating room.
  • The described apparatus provides excellent conditions for the study of scintillations properties in plastic and crystal scintillating detector materials in static and dynamic electron and gamma radiation fields using the light transparency measurement. The apparatus is consist of two main parts: an optical bench and a specially developed double beam spectrophotometer. The optical bench is installed at the accelerator output and serves for setting of investigated samples. The spectrophotometer, which is situated in a radiation protected room, is based on the 256-diode array spectrometer with optical fiber input LASP 2; the spectral range from 350 to 735 nm is analyzed simultaneously. All the apparatus parts are controlled by PC from a radiation protected operating room. (en)
  • Popsané zařízení poskytuje vyborné podmínky pro studium scintilačních vlastností plastových a krystalových scintilačních detekčních materiálů za použití měření světelné transmise, a to jak ve statickém tak dynamickém poli záření gama a elektronů. Zařízení se skládá ze dvou hlavních částí: optické lavice a speciálně vyvinutého dvoupaprskového spektrofotometru. Optická lavice je instalována na výstupu urychlovače a slouží pro umístění zkoumaných vzorků. Spektrofotometr, který se nachází v radiačně chráněné místnosti, je založen na 256-diodovém spetrometru s optickým vstupem LASP 2; spektrální rozsah od 350 do 735 nm je analyzován současne. všechny části zařízení jsou ovládany z radiačně chráněné mistnosti pomocí PC. (cs)
Title
  • Zařízení pro online měření transmise scintilačních detekčních materiálů v gama a elektronovém poli (cs)
  • Apparatus for On-line Transparency Measurement of Scintillation Detector Materials in Gamma and Electron Radiation Fields
  • Apparatus for On-line Transparency Measurement of Scintillation Detector Materials in Gamma and Electron Radiation Fields (en)
skos:prefLabel
  • Zařízení pro online měření transmise scintilačních detekčních materiálů v gama a elektronovém poli (cs)
  • Apparatus for On-line Transparency Measurement of Scintillation Detector Materials in Gamma and Electron Radiation Fields
  • Apparatus for On-line Transparency Measurement of Scintillation Detector Materials in Gamma and Electron Radiation Fields (en)
skos:notation
  • RIV/68407700:21340/04:04096373!RIV08-MSM-21340___
http://linked.open.../vavai/riv/strany
  • 592;593
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 555016
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21340/04:04096373
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • scintilation materials, radiation damage, transparency measurement (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [E489533E9EED]
http://linked.open...v/mistoKonaniAkce
  • Praha
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • Proceedings of Workshop 2004
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Chvátil, David
  • Finger, Miroslav
  • Mikeš, P.
  • Šulc, M.
  • Blaha, Jan
  • Vognar, M.
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • České vysoké učení technické v Praze
https://schema.org/isbn
  • 80-01-02945-X
http://localhost/t...ganizacniJednotka
  • 21340
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 94 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software