| - 3 kW generator is proposed for combined heat and power production with Stirling engine. Solution of the given complex problem was based on a detailed analysis and critical evaluation of the existing scientific knowledge and the know-how, and involved the application of general power engineering, thermodynamics and thermokinetics, computer-aided design, applied mechanics, strength of materials, material engineering, production technology, electrical engineering and technical experiment. Computational modeling of real working cycles of external combustion engines and application of virtual prototypes used when optimizing their mechanical structures enabled to shorten considerably many development tasks.
- 3 kW generator is proposed for combined heat and power production with Stirling engine. Solution of the given complex problem was based on a detailed analysis and critical evaluation of the existing scientific knowledge and the know-how, and involved the application of general power engineering, thermodynamics and thermokinetics, computer-aided design, applied mechanics, strength of materials, material engineering, production technology, electrical engineering and technical experiment. Computational modeling of real working cycles of external combustion engines and application of virtual prototypes used when optimizing their mechanical structures enabled to shorten considerably many development tasks. (en)
|
Title
| - Generator for 3 kW Stirling Engine
- Generator for 3 kW Stirling Engine (en)
|
skos:prefLabel
| - Generator for 3 kW Stirling Engine
- Generator for 3 kW Stirling Engine (en)
|
skos:notation
| - RIV/00216305:26210/11:PR25840!RIV12-MSM-26210___
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...onomickeParametry
| - Užitím generátoru o výkonu 3 kW v jednotce pro kombinovanou výrobu tepla a elektrické energie se Stirlingovým motorem lze dosáhnout ekonomických a ekologických úspor.
|
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26210/11:PR25840
|
http://linked.open...terniIdentifikace
| |
http://linked.open...riv/jazykVysledku
| |
http://linked.open...vai/riv/kategorie
| |
http://linked.open.../riv/klicovaSlova
| - Generator, powerplant, virtual prototype, heat and power production (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...okalizaceVysledku
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...echnickeParametry
| - Funkční vzorek generátoru o výkonu 3 kW byl na základě virtuálních prototypů vyroben a po experimentálním ověření je využíván jako laboratorní zařízení na pracovišti řešitele: laboratoř č. C3, Ústav automobilního a dopravního inženýrství, Fakulta strojního inženýrství, Vysoké učení technické v Brně, Technická 2896/2, 616 69 Brno.
|
http://linked.open...iv/tvurceVysledku
| - Kaplan, Zdeněk
- Novotný, Pavel