Attributes | Values |
---|
rdf:type
| |
Description
| - Recently, the role of energy savings in indoor air quality deterioration has been extensively emphasized, predominantly in the context of significant air exchange rate reduction as a result of home energy retrofits. In case of refurbishment of existing buildings, the effect of energy-efficient technologies on indoor radon concentration is considerably complex and has to be carefully evaluated in respect to radon entry rate and air exchange rate alteration. For the purpose of detailed analysis of radon entry pathways, the unique infiltration experiment has been carried out using the tracer gas (N2O) method application in field conditions. Significant amount of experimental works has been done to provide an independent assessment of radon entry rate and air-exchange rate facilitating the analysis of fundamental factors influencing the indoor radon variations (e.g. indoor-outdoor pressure difference induced by wind; stack effect; heating, ventilation, and air conditioning systems operation).
- Recently, the role of energy savings in indoor air quality deterioration has been extensively emphasized, predominantly in the context of significant air exchange rate reduction as a result of home energy retrofits. In case of refurbishment of existing buildings, the effect of energy-efficient technologies on indoor radon concentration is considerably complex and has to be carefully evaluated in respect to radon entry rate and air exchange rate alteration. For the purpose of detailed analysis of radon entry pathways, the unique infiltration experiment has been carried out using the tracer gas (N2O) method application in field conditions. Significant amount of experimental works has been done to provide an independent assessment of radon entry rate and air-exchange rate facilitating the analysis of fundamental factors influencing the indoor radon variations (e.g. indoor-outdoor pressure difference induced by wind; stack effect; heating, ventilation, and air conditioning systems operation). (en)
|
Title
| - Radon entry rate analyses using in-situ tracer gas method aplication (en)
- Radon entry rate analyses using in-situ tracer gas method aplication
|
skos:prefLabel
| - Radon entry rate analyses using in-situ tracer gas method aplication (en)
- Radon entry rate analyses using in-situ tracer gas method aplication
|
skos:notation
| - RIV/86652052:_____/13:#0000171!RIV14-TA0-86652052
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/86652052:_____/13:#0000171
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - radon entry; air-exchange rate; tracer gas (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Froňka, Aleš
- Jílek, Karel
|