| - Heat exchange is a classical thermal process which occurs in a wide range of industrial technologies, particularly in the energetic and chemical industry. The paper is focused on a problem of production of liquid (water) with a given temperature course in time. Heating or cooling of inflow water is realized by a heat exchanger which is equipped with heating element and a spiral tube which can serve as a cooling element. The water inside the exchanger can serve as a tank for various chemical or technological operations. The need for tempered water is quite common in many industry branches. From the control point of view, the controlled system is asymmetrical; it has two inputs (cooling and heating) and one output ? temperature of water inside the exchanger. A set of predictive controllers were designed to cope with the problem and these controllers were verified and compared by a realtime control of Multifunction Process Control Teaching System (MPCTS) ? the Armfield PCT 40.
- Heat exchange is a classical thermal process which occurs in a wide range of industrial technologies, particularly in the energetic and chemical industry. The paper is focused on a problem of production of liquid (water) with a given temperature course in time. Heating or cooling of inflow water is realized by a heat exchanger which is equipped with heating element and a spiral tube which can serve as a cooling element. The water inside the exchanger can serve as a tank for various chemical or technological operations. The need for tempered water is quite common in many industry branches. From the control point of view, the controlled system is asymmetrical; it has two inputs (cooling and heating) and one output ? temperature of water inside the exchanger. A set of predictive controllers were designed to cope with the problem and these controllers were verified and compared by a realtime control of Multifunction Process Control Teaching System (MPCTS) ? the Armfield PCT 40. (en)
|
Title
| - Control of Heat Exchanger using Predictive Approach
- Control of Heat Exchanger using Predictive Approach (en)
|
skos:prefLabel
| - Control of Heat Exchanger using Predictive Approach
- Control of Heat Exchanger using Predictive Approach (en)
|
skos:notation
| - RIV/70883521:28140/10:63508851!RIV11-GA0-28140___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(1M0567), P(GP102/06/P286)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/70883521:28140/10:63508851
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Predictive control; Recursive least squares method; TISO system; Heat exchanger; Real-time control (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Modelling, Identification, and Control
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Bobál, Vladimír
- Chalupa, Petr
- Novák, Jakub
|