Attributes | Values |
---|
rdf:type
| |
rdfs:seeAlso
| |
Description
| - The new RAMARN system for radon volume activity measurement was developed in 2003 and since this year it has been used. RAMARN system consists of a plastic chamber of conical form with 0,5 l of capacity and a detector Kodak LR 115 that is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited decay products of radon. Kodak has a spektrometric charakter - the traks are visualized only for Alpha particles with energies between 1 and 3 MeV, that touch the foil. Thus the effective volume has a lens shape. The response therefore sorresponds to diffused radon and half of 218 Po born by radon gas decay. The experiments were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleology.
- The new RAMARN system for radon volume activity measurement was developed in 2003 and since this year it has been used. RAMARN system consists of a plastic chamber of conical form with 0,5 l of capacity and a detector Kodak LR 115 that is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited decay products of radon. Kodak has a spektrometric charakter - the traks are visualized only for Alpha particles with energies between 1 and 3 MeV, that touch the foil. Thus the effective volume has a lens shape. The response therefore sorresponds to diffused radon and half of 218 Po born by radon gas decay. The experiments were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleology. (en)
- Nový stopový detektor RAMARN pro měření objemové aktivity radonu byl vyvinut v roce 2003 a od té doby je používán. Detektor RAMARN sestává z platikové nádoby kónického tvaru o objemu 0,5 l a detektoru Kodak LR 115, který je umístěn na dně difisní komůrky. Velikost byla zvolena kvůli možnému vlivu depozice přeměnových produktů radonu. Kodak má spektrometrické vlastnosti - stopy jsou vizualizovány jen pro alfa částice o energii mezi 1MeV a 3 MeV (cs)
|
Title
| - Effective dose assessment for works in caves in the Czech Republic: experiments with passive radon detectors
- Ohad efektivní dávky pro pracovníky jeskyní České republiky: esperimenty s pasivními detektory (cs)
- Effective dose assessment for works in caves in the Czech Republic: experiments with passive radon detectors (en)
|
skos:prefLabel
| - Effective dose assessment for works in caves in the Czech Republic: experiments with passive radon detectors
- Ohad efektivní dávky pro pracovníky jeskyní České republiky: esperimenty s pasivními detektory (cs)
- Effective dose assessment for works in caves in the Czech Republic: experiments with passive radon detectors (en)
|
skos:notation
| - RIV/70565813:_____/08:#0000146!RIV08-SUJ-70565813
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/70565813:_____/08:#0000146
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| |
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...i/riv/kodPristupu
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Burian, Ivo
- Thinová, Lenka
|
http://linked.open...n/vavai/riv/zamer
| |