Attributes | Values |
---|
rdf:type
| |
Description
| - MutS, a protein involved in DNA mismatch repair, recognizes mispaired and unpaired bases in duplex DNA. We have previously used MutS in an electrochemical double-surface technique (DST) for in-vitro detection of point mutations in DNA. The DST involved binding of unlabeled MutS to DNA heteroduplexes at the surface of magnetic beads followed by a highly sensitive electrochemical determination of the protein by measurement of a catalytic protein signal (peak H) at mercury electrodes. Detection of MutS using a peak resulting from oxidation of tyrosine and tryptophan residues of the protein at a carbon-paste electrode (CPE) was also possible but was approximately three orders of magnitude less sensitive. In this work we present an optimized technique for ex-situ voltammetric determination of MutS at a CPE. Choice of optimum experimental conditions (pH of supporting electrolyte, square-wave voltammetry settings, etc.) resulted in substantial improvement of the sensitivity of the assay, enabling detection of approximately 140 pg (1.6 fmol protein monomer) MutS in a 5-mu L sample. The sensitivity was increased further by acid hydrolysis of the protein before measurement. The hydrolyzed protein was detectable down to 5 pg (approx. 56 amol) MutS in 5 mu L solution. By using the DST combined with determination of the bound unlabeled MutS at the CPE we demonstrated selective interactions of the protein with single-base mismatches and discrimination among different base mispairs in 30-mer or 95-mer DNA duplexes. In agreement with previous studies, binding of the protein to the 30-mer substrates followed the trend G:T >> C:A > A:A > C:T > homoduplex. The electrochemical data were confirmed by use of an independent technique-a quartz-crystal microbalance for real-time monitoring of MutS interactions with DNA duplexes containing different base mispairs. By using the electrochemical DST a G:T mismatch was detectable in up to 1000-fold excess of homoduplex DNA.
- MutS, a protein involved in DNA mismatch repair, recognizes mispaired and unpaired bases in duplex DNA. We have previously used MutS in an electrochemical double-surface technique (DST) for in-vitro detection of point mutations in DNA. The DST involved binding of unlabeled MutS to DNA heteroduplexes at the surface of magnetic beads followed by a highly sensitive electrochemical determination of the protein by measurement of a catalytic protein signal (peak H) at mercury electrodes. Detection of MutS using a peak resulting from oxidation of tyrosine and tryptophan residues of the protein at a carbon-paste electrode (CPE) was also possible but was approximately three orders of magnitude less sensitive. In this work we present an optimized technique for ex-situ voltammetric determination of MutS at a CPE. Choice of optimum experimental conditions (pH of supporting electrolyte, square-wave voltammetry settings, etc.) resulted in substantial improvement of the sensitivity of the assay, enabling detection of approximately 140 pg (1.6 fmol protein monomer) MutS in a 5-mu L sample. The sensitivity was increased further by acid hydrolysis of the protein before measurement. The hydrolyzed protein was detectable down to 5 pg (approx. 56 amol) MutS in 5 mu L solution. By using the DST combined with determination of the bound unlabeled MutS at the CPE we demonstrated selective interactions of the protein with single-base mismatches and discrimination among different base mispairs in 30-mer or 95-mer DNA duplexes. In agreement with previous studies, binding of the protein to the 30-mer substrates followed the trend G:T >> C:A > A:A > C:T > homoduplex. The electrochemical data were confirmed by use of an independent technique-a quartz-crystal microbalance for real-time monitoring of MutS interactions with DNA duplexes containing different base mispairs. By using the electrochemical DST a G:T mismatch was detectable in up to 1000-fold excess of homoduplex DNA. (en)
|
Title
| - Label-free voltammetric detection of single nucleotide mismatches recognized by MutS protein
- Label-free voltammetric detection of single nucleotide mismatches recognized by MutS protein (en)
|
skos:prefLabel
| - Label-free voltammetric detection of single nucleotide mismatches recognized by MutS protein
- Label-free voltammetric detection of single nucleotide mismatches recognized by MutS protein (en)
|
skos:notation
| - RIV/62156489:43210/07:00107888!RIV12-MSM-43210___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/62156489:43210/07:00107888
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - electrochemical detection; muts; molecular recognize (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - DE - Spolková republika Německo
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Analytical and Bioanalytical Chemistry
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Fojta, Miroslav
- Kizek, René
- Masařík, Michal
- Paleček, Emil
- Cahová, Kateřina
|
issn
| |
number of pages
| |
http://localhost/t...ganizacniJednotka
| |
is http://linked.open...avai/riv/vysledek
of | |