About: PD Behaviour of Basic Test Arrangements under Different Measurement Conditions     Goto   Sponge   Distinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The PD behaviour of so-called basic test arrangements as for corona discharge or other discharge sources seems to be well known from the physical point of view. On the other hand the measurement results and, in the same manner, their identification and interpretation can be different, because this is depending on the measurement or evaluation conditions. Therefore some typical basic arrangements representing corona discharges as needle-plane, needle-plane with insulating sheet and needle -sphere as well as artificial cavity into insulating material were investigated. In a previous paper the pd behaviour of the corona set- ups in air were already discussed. Additional to that the pd behaviour of typical internal pd source under different measurement condition is described. In this paper the most recognized values are compared at the well defined laboratory set ups as defined. During these investigations the standard evaluation methods according to IEC 60270, PRPD pattern and pulse sequence analysis is done. By comparing these three evaluation types the most significant method for the classification of failure types is discussed. For closer evaluation of image based evaluation methods like PRPD pattern and pulse sequence analysis different methods of classification are discussed. The presented results show surprisingly characteristic shapes of the PD pattern, which allow the better classification of the types of PD sources and their identification respectively.
  • The PD behaviour of so-called basic test arrangements as for corona discharge or other discharge sources seems to be well known from the physical point of view. On the other hand the measurement results and, in the same manner, their identification and interpretation can be different, because this is depending on the measurement or evaluation conditions. Therefore some typical basic arrangements representing corona discharges as needle-plane, needle-plane with insulating sheet and needle -sphere as well as artificial cavity into insulating material were investigated. In a previous paper the pd behaviour of the corona set- ups in air were already discussed. Additional to that the pd behaviour of typical internal pd source under different measurement condition is described. In this paper the most recognized values are compared at the well defined laboratory set ups as defined. During these investigations the standard evaluation methods according to IEC 60270, PRPD pattern and pulse sequence analysis is done. By comparing these three evaluation types the most significant method for the classification of failure types is discussed. For closer evaluation of image based evaluation methods like PRPD pattern and pulse sequence analysis different methods of classification are discussed. The presented results show surprisingly characteristic shapes of the PD pattern, which allow the better classification of the types of PD sources and their identification respectively. (en)
Title
  • PD Behaviour of Basic Test Arrangements under Different Measurement Conditions
  • PD Behaviour of Basic Test Arrangements under Different Measurement Conditions (en)
skos:prefLabel
  • PD Behaviour of Basic Test Arrangements under Different Measurement Conditions
  • PD Behaviour of Basic Test Arrangements under Different Measurement Conditions (en)
skos:notation
  • RIV/49777513:23220/12:43915801!RIV13-MSM-23220___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED2.1.00/03.0094), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 158031
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23220/12:43915801
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • partial discharges, diffrent frequency ranges, corona, internal partial discharges (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [CF5AD1E30C3A]
http://linked.open...v/mistoKonaniAkce
  • Bali-Indonesia
http://linked.open...i/riv/mistoVydani
  • Red Hook
http://linked.open...i/riv/nazevZdroje
  • Proceedings of 2012 IEEE International Conference on Condition Monitoring and Diagnosis
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Mráz, Petr
  • Pihera, Josef
  • Haller, Rainer
  • Kornhuber, Stefan
  • Boltze, Matthias
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • IEEE
https://schema.org/isbn
  • 978-1-4673-1020-8
http://localhost/t...ganizacniJednotka
  • 23220
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software