| - The article reports on certain artifacts that emerge during the in vitro diffusion-weighted imaging of physical samples. In this context, the authors analyze the influence of magnetic field inhomogeneity, temperature, or eddy currents and consider procedures to mitigation of the artifacts. A technique reducing the examined spurious effects was designed, experimentally verified, and denominated as the three measurements method. The technique proved to be useful mainly for the evaluation of a DWI image measured with a diffusion gradient in the z axis, where the relative measurement error decreased to 3.38% (during measurement using two images, the relative error was greater than 19%). For small errors within the measurement of diffusion constants of a deionised water sample (<5%) it is necessary to select a b-factor value larger than 200x10^6 s.m-2. Temperature stabilisation with an accuracy better than 0.1 degree of celsius during the entire measuring process is a necessary prerequisite for the measure
- The article reports on certain artifacts that emerge during the in vitro diffusion-weighted imaging of physical samples. In this context, the authors analyze the influence of magnetic field inhomogeneity, temperature, or eddy currents and consider procedures to mitigation of the artifacts. A technique reducing the examined spurious effects was designed, experimentally verified, and denominated as the three measurements method. The technique proved to be useful mainly for the evaluation of a DWI image measured with a diffusion gradient in the z axis, where the relative measurement error decreased to 3.38% (during measurement using two images, the relative error was greater than 19%). For small errors within the measurement of diffusion constants of a deionised water sample (<5%) it is necessary to select a b-factor value larger than 200x10^6 s.m-2. Temperature stabilisation with an accuracy better than 0.1 degree of celsius during the entire measuring process is a necessary prerequisite for the measure (en)
|
Title
| - Diffusion MRI: magnetic field inhomogeneities mitigation
- Diffusion MRI: magnetic field inhomogeneities mitigation (en)
|
skos:prefLabel
| - Diffusion MRI: magnetic field inhomogeneities mitigation
- Diffusion MRI: magnetic field inhomogeneities mitigation (en)
|
skos:notation
| - RIV/00216305:26220/12:PU99793!RIV13-GA0-26220___
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GAP102/11/0318), P(GAP102/12/1104), S
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26220/12:PU99793
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - correction, diffusion, inhomogeneity, eddy currents, magnetic resonance (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Measurement Science Review
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Bartušek, Karel
- Dokoupil, Zdeněk
- Gescheidtová, Eva
- Marcoň, Petr
|