About: Heat Storage Capability on Asymmetrically Cooled Wall by Transient Heat Flow     Goto   Sponge   Distinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • A strong rationale for energy efficiency and its savings in buildings aims to further develop new concepts as well as more accurate calculation and simulation techniques. In the paper is described efficient implementation of basic relations governing the thermal energy transfer process within the vertical wall into a state-variable model of wall segment with time-dependent properties.
  • A strong rationale for energy efficiency and its savings in buildings aims to further develop new concepts as well as more accurate calculation and simulation techniques. In the paper is described efficient implementation of basic relations governing the thermal energy transfer process within the vertical wall into a state-variable model of wall segment with time-dependent properties. (en)
Title
  • Heat Storage Capability on Asymmetrically Cooled Wall by Transient Heat Flow
  • Heat Storage Capability on Asymmetrically Cooled Wall by Transient Heat Flow (en)
skos:prefLabel
  • Heat Storage Capability on Asymmetrically Cooled Wall by Transient Heat Flow
  • Heat Storage Capability on Asymmetrically Cooled Wall by Transient Heat Flow (en)
skos:notation
  • RIV/00216275:25310/11:39892192!RIV12-MSM-25310___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM0021627501)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 201816
http://linked.open...ai/riv/idVysledku
  • RIV/00216275:25310/11:39892192
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • simulation model; thermal storage; heat transfer coefficient by convection; transient heat flow (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [6CD83FC9F639]
http://linked.open...v/mistoKonaniAkce
  • Praha
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • 19th Annual Conference Proceedings: Technical Computing Prague 2011
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hach, Lubos
  • Katoh, Yasuo
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Vysoká škola chemicko-technologická v Praze
https://schema.org/isbn
  • 978-80-7080-794-1
http://localhost/t...ganizacniJednotka
  • 25310
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software