About: Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution     Goto   Sponge   Distinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • We used the data of 50 CT examinations performed due to suspected pulmonary embolism with any pathological finding except consolidation of the parenchyma. The patients underwent CT angiography of the pulmonary arteries on a dual-source CT (DSCT), with the two tubes independently operated at 140 and 80 kV. By exploiting the dual-energy information, iodine distribution maps were obtained in addition to the conventional CT images which served as a marker of pulmonary perfusion. Minimum intensity projections (MinIP) were used as a marker of air content. By comparing the iodine distribution maps and MinIP images, it was possible to differentiate between the following templates of lung parenchyma: A--normal iodine and air distribution; B--iodine content deficit with minimal or with no redistribution of air; C--reduced iodine content and increased content of air; D--deficit of iodine content and increased content of air; E--increased iodine content and normal content of air; F--increased iodine content and reduced content of air; G--reduced perfusion and reduced content of air. The type A (five cases) was typical for the pulmonary embolism with preserved normal conditions of perfusion and ventilation. Type B (18 cases) occurred in pulmonary embolism; type C was found in case of inflammation of small respiratory airways (five cases); emphysema was typical for type D (nine cases); increased perfusion was observed in the parenchyma preserved from emphysema or preserved from embolism in cases of emphysema or pulmonary embolism; type F occurred in pulmonary interstitial edema (four cases) both with pulmonary infection; finally type G was found in interstitial lung diseases (five cases).
  • We used the data of 50 CT examinations performed due to suspected pulmonary embolism with any pathological finding except consolidation of the parenchyma. The patients underwent CT angiography of the pulmonary arteries on a dual-source CT (DSCT), with the two tubes independently operated at 140 and 80 kV. By exploiting the dual-energy information, iodine distribution maps were obtained in addition to the conventional CT images which served as a marker of pulmonary perfusion. Minimum intensity projections (MinIP) were used as a marker of air content. By comparing the iodine distribution maps and MinIP images, it was possible to differentiate between the following templates of lung parenchyma: A--normal iodine and air distribution; B--iodine content deficit with minimal or with no redistribution of air; C--reduced iodine content and increased content of air; D--deficit of iodine content and increased content of air; E--increased iodine content and normal content of air; F--increased iodine content and reduced content of air; G--reduced perfusion and reduced content of air. The type A (five cases) was typical for the pulmonary embolism with preserved normal conditions of perfusion and ventilation. Type B (18 cases) occurred in pulmonary embolism; type C was found in case of inflammation of small respiratory airways (five cases); emphysema was typical for type D (nine cases); increased perfusion was observed in the parenchyma preserved from emphysema or preserved from embolism in cases of emphysema or pulmonary embolism; type F occurred in pulmonary interstitial edema (four cases) both with pulmonary infection; finally type G was found in interstitial lung diseases (five cases). (en)
Title
  • Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution
  • Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution (en)
skos:prefLabel
  • Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution
  • Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution (en)
skos:notation
  • RIV/00216208:11140/11:10106855!RIV12-MSM-11140___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM0021620819)
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 225252
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11140/11:10106855
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Lung perfusion; Pulmonary circulation; Dual-energy computed tomography; Dual-source computed tomography (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [549C89534347]
http://linked.open...i/riv/nazevZdroje
  • European Journal of Radiology
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 77
http://linked.open...iv/tvurceVysledku
  • Baxa, Jan
  • Bednářová, Alena
  • Ferda, Jiří
  • Kreuzberg, Boris
  • Matějovič, Martin
  • Mírka, Hynek
  • Ferdová, Eva
  • Flohr, Thomas
  • Schmidt, Bernhard
http://linked.open...ain/vavai/riv/wos
  • 000286623100018
http://linked.open...n/vavai/riv/zamer
issn
  • 0720-048X
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.ejrad.2009.08.005
http://localhost/t...ganizacniJednotka
  • 11140
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 39 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software