Attributes | Values |
---|
rdf:type
| |
rdfs:seeAlso
| |
Description
| - The main goal of the project is to improve the understanding how the basic parameters of a vectorially compensated fluxgate magnetometer are influenced by its sensor head construction, i.e. material selection, mechanical structure and electrical design. The basic parameters are: noise, linearity, offset temperature stability, sensitivity temperature stability and orthogonality temperature stability. Scalar calibration technique extended by specific hardware allows to study most of these basic characteristics. Previous research has indicated that the available hardware equipment limits the accuracy of the measurement and thus the possibility to fully understand the behavior of the sensor. The secondary goal is thus the development of improved versions of the necessary hardware equipment, i.e. fluxgate magnetometer excitation and signal conditioning electronics with digital data output, non-magnetic platform for automatic positioning of measured samples with improved magnetic cleanliness and several variants of the magnetometer sensor heads. (en)
- Hlavním cílem projektu je zlepšit porozumění jak jsou ovlivněny základní parametry vektorově kompenzovaného magnetometru konstrukcí senzorové hlavice, tj. výběrem materiálů, mechanickou konstrukcí a elektrickým zapojením. Mezi základní parametry patří: šum, linearita, teplotní stabilita offsetu, teplotní stabilita citlivosti a teplotní stabilita orthogonality. Technika skalární kalibrace rozšířená pomocí specifického hardwarového vybavení umožňuje studovat většinu z těchto základních charakteristik. Předchozí výzkum ukázal, že dostupné hardwarové vybavení limituje přesnost měření a tudíž i možnost zcela porozumět chování senzoru. Sekundárním cílem projektu je tedy vývoj vyspělejších verzí potřebných hardwarových prostředků, tj. elektroniky pro buzení a zpracování signálu fluxgate senzoru s digitálním výstupem, nemagnetické platformy pro automatické provedení sběru dat pro skalární kalibraci s vylepšenou magnetickou čistotou a několika nových variant senzorových hlavic magnetometru.
|
Title
| - Study of a sensor construction impact on vector magnetometer parameters using extended scalar calibration methods (en)
- Studium vlivu konstrukce senzoru na parametry vektorového magnetometru metodou rozšířené skalární kalibrace
|
skos:notation
| |
http://linked.open...avai/cep/aktivita
| |
http://linked.open...kovaStatniPodpora
| |
http://linked.open...ep/celkoveNaklady
| |
http://linked.open...datumDodatniDoRIV
| |
http://linked.open...i/cep/druhSouteze
| |
http://linked.open...ep/duvernostUdaju
| |
http://linked.open.../cep/fazeProjektu
| |
http://linked.open...ai/cep/hlavniObor
| |
http://linked.open...vai/cep/kategorie
| |
http://linked.open.../cep/klicovaSlova
| - sensor, magnetometer, scalar calibration (en)
|
http://linked.open...ep/partnetrHlavni
| |
http://linked.open...inujicichPrijemcu
| |
http://linked.open...cep/pocetPrijemcu
| |
http://linked.open...ocetSpoluPrijemcu
| |
http://linked.open.../pocetVysledkuRIV
| |
http://linked.open...enychVysledkuVRIV
| |
http://linked.open...lneniVMinulemRoce
| |
http://linked.open.../prideleniPodpory
| |
http://linked.open...iciPoslednihoRoku
| |
http://linked.open...atUdajeProjZameru
| |
http://linked.open.../vavai/cep/soutez
| |
http://linked.open...usZobrazovaneFaze
| |
http://linked.open...ai/cep/typPojektu
| |
http://linked.open...ep/ukonceniReseni
| |
http://linked.open...ep/zahajeniReseni
| |
http://linked.open...tniCyklusProjektu
| |
http://linked.open.../cep/klicoveSlovo
| |
is http://linked.open...vavai/riv/projekt
of | |
is http://linked.open...vavai/cep/projekt
of | |