About: Protection of cultural heritage by real-time corrosion monitoring     Goto   Sponge   Distinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • There are many factors affecting air corrosivity, but it is only the temperature and sometimes the relative humidity that are controlled and monitored in indoor premises where valuable and culturally significant objects are stored or displayed. Additional anti-corrosion measures are usually applied only when often-irreplaceable historical objects have already been affected. Information on the actual corrosivity of the atmosphere is crucial to effective corrosion protection and there is a strong need for professionals active in the protection of cultural heritage to have a tool enabling real-time assessment of the air corrosivity. In a project financed within FP6, prototypes of loggers for continuous measurement of the corrosion rate of selected technical metals in atmospheric conditions were developed. The electronic unit measures and records changes in the electrical resistance of a thin metal track applied on an insulating substrate. The developed concept offers several important advantages, such as on-line and real-time monitoring, small size, easy replaceable metal sensors, remote data access, and automatic data delivery via e-mail. The main objectives of the present project that will allow for the application of the logger in the cultural heritage sphere are: (1) To develop new sensors such as silver, lead, and metal alloys simulating more closely historical materials. (2) To improve currently available sensors by decreasing the metal layer thickness to 50–500 nm to provide higher sensitivity. (3) To improve the electronic part of the logger with new measurement ranges, a universal communication interface, and better water-tightness. (4) To adapt the electronic logger and software for single measurements on sensors exposed separately. (5) To develop software that provides user-friendly data handling and makes data interpretation simple by referring to available standards or recommendations. (en)
  • There are many factors affecting air corrosivity, but it is only the temperature and sometimes the relative humidity that are controlled and monitored in indoor premises where valuable and culturally significant objects are stored or displayed. Additional anti-corrosion measures are usually applied only when often-irreplaceable historical objects have already been affected. Information on the actual corrosivity of the atmosphere is crucial to effective corrosion protection and there is a strong need for professionals active in the protection of cultural heritage to have a tool enabling real-time assessment of the air corrosivity. In a project financed within FP6, prototypes of loggers for continuous measurement of the corrosion rate of selected technical metals in atmospheric conditions were developed. The electronic unit measures and records changes in the electrical resistance of a thin metal track applied on an insulating substrate. The developed concept offers several important advantages, such as on-line and real-time monitoring, small size, easy replaceable metal sensors, remote data access, and automatic data delivery via e-mail. The main objectives of the present project that will allow for the application of the logger in the cultural heritage sphere are: (1) To develop new sensors such as silver, lead, and metal alloys simulating more closely historical materials. (2) To improve currently available sensors by decreasing the metal layer thickness to 50–500 nm to provide higher sensitivity. (3) To improve the electronic part of the logger with new measurement ranges, a universal communication interface, and better water-tightness. (4) To adapt the electronic logger and software for single measurements on sensors exposed separately. (5) To develop software that provides user-friendly data handling and makes data interpretation simple by referring to available standards or recommendations. (cs)
Title
  • Protection of cultural heritage by real-time corrosion monitoring (en)
  • Protection of cultural heritage by real-time corrosion monitoring (cs)
http://linked.open...vai/cislo-smlouvy
http://linked.open...avai/druh-souteze
http://linked.open...domain/vavai/faze
http://linked.open...vavai/hlavni-obor
http://linked.open...vai/vedlejsi-obor
http://linked.open...vavai/id-aktivity
http://linked.open.../vavai/id-souteze
http://linked.open...n/vavai/kategorie
http://linked.open...vai/klicova-slova
  • Corrosion monitoring, atmospheric corrosion, metal protection, cultural heritage, museum, archive, library, exhibition (en)
http://linked.open...avai/konec-reseni
http://linked.open...nujicich-prijemcu
http://linked.open...avai/poskytovatel
http://linked.open...avai/start-reseni
http://linked.open...ai/statni-podpora
http://linked.open...vavai/typProjektu
http://linked.open...ai/uznane-naklady
http://linked.open...ai/pocet-prijemcu
http://linked.open...cet-spoluprijemcu
http://linked.open...ai/pocet-vysledku
http://linked.open...ku-zverejnovanych
is http://linked.open...ain/vavai/projekt of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 32 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software