About: Software calculation tool for light savings in the buildings compared with real measured data     Goto   Sponge   Distinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This paper describes modeling of possible savings in lighting systems of artificial lighting, working in combination with daylight. The proposed model works with overcast sky daylight (CIE). Based on knowledge of geographical position, day and time, the calculations are done in the conditions of unshadowed outdoor illuminance levels. From this figure (when daylight factor is known) illuminance caused by daylight can be gain in the different parts of the room. By controlling the artificial lighting (dimming) to constant cumulative value (daylight plus artificial light) in the areas of visual tasks, then it is possible to determine potential of savings in areas with controlled lighting system and without it. According to this model (calculation), we can consider a suitability of the dimmable lighting systems in the specific work areas and make recommendations to reduce energy requirements of buildings in energy audits. The sample model was compared with measurement of illuminance in the model room. The dimmed lighting systems was controlled by the KNX system via the light sensor.
  • This paper describes modeling of possible savings in lighting systems of artificial lighting, working in combination with daylight. The proposed model works with overcast sky daylight (CIE). Based on knowledge of geographical position, day and time, the calculations are done in the conditions of unshadowed outdoor illuminance levels. From this figure (when daylight factor is known) illuminance caused by daylight can be gain in the different parts of the room. By controlling the artificial lighting (dimming) to constant cumulative value (daylight plus artificial light) in the areas of visual tasks, then it is possible to determine potential of savings in areas with controlled lighting system and without it. According to this model (calculation), we can consider a suitability of the dimmable lighting systems in the specific work areas and make recommendations to reduce energy requirements of buildings in energy audits. The sample model was compared with measurement of illuminance in the model room. The dimmed lighting systems was controlled by the KNX system via the light sensor. (en)
Title
  • Software calculation tool for light savings in the buildings compared with real measured data
  • Software calculation tool for light savings in the buildings compared with real measured data (en)
skos:prefLabel
  • Software calculation tool for light savings in the buildings compared with real measured data
  • Software calculation tool for light savings in the buildings compared with real measured data (en)
skos:notation
  • RIV/61989100:27240/13:86086710!RIV14-MSM-27240___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 106041
http://linked.open...ai/riv/idVysledku
  • RIV/61989100:27240/13:86086710
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Dimming; Indoor lighting; overcast sky; Daylight; Savings (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [7BF19A39D07E]
http://linked.open...v/mistoKonaniAkce
  • Kouty nad Desnou
http://linked.open...i/riv/mistoVydani
  • Ostrava
http://linked.open...i/riv/nazevZdroje
  • Proceedings of the 14th International Scientific Conference Electric Power Engineering 2013
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Novák, Tomáš
  • Sokanský, Karel
  • Šumpich, Jan
  • Carbol, Zbyněk
http://linked.open...vavai/riv/typAkce
http://linked.open...ain/vavai/riv/wos
  • 000321920400133
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Vysoká škola báňská - Technická univerzita Ostrava
https://schema.org/isbn
  • 978-80-248-2988-3
http://localhost/t...ganizacniJednotka
  • 27240
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software