Attributes | Values |
---|
rdf:type
| |
Description
| - Radon is radioactive gas, which can leak into buildings, where it is concentrating and endangering health of inhabitants. In terms of human health protection at work and in residential buildings, radon can cause high exposures. The first step for quality protection against radon is well done measurements. This contribution is focused on a method of evaluation of the integrated electret ion chamber system RM-1 often used in the Czech Republic. This contribution reports five-week long measurements in real conditions, statistical analyses of datasets and a verification of the evaluation method recommended by the manufacturer of the electret device. The statistical verification was carried out by multiple linear regressions using the Statgraphics Plus 5.1 software and symbolic regressions using the Eureqa software version 0.79 beta software. Finally, results of integrated measurements are compared with ones taken from the continual radon monitor Radim3As.
- Radon is radioactive gas, which can leak into buildings, where it is concentrating and endangering health of inhabitants. In terms of human health protection at work and in residential buildings, radon can cause high exposures. The first step for quality protection against radon is well done measurements. This contribution is focused on a method of evaluation of the integrated electret ion chamber system RM-1 often used in the Czech Republic. This contribution reports five-week long measurements in real conditions, statistical analyses of datasets and a verification of the evaluation method recommended by the manufacturer of the electret device. The statistical verification was carried out by multiple linear regressions using the Statgraphics Plus 5.1 software and symbolic regressions using the Eureqa software version 0.79 beta software. Finally, results of integrated measurements are compared with ones taken from the continual radon monitor Radim3As. (en)
|
Title
| - STATISTICAL VERIFICATION OF THE METHOD OF EVALUATION THE SHORT TERM RADON INTEGRATED MEASUREMENTS
- STATISTICAL VERIFICATION OF THE METHOD OF EVALUATION THE SHORT TERM RADON INTEGRATED MEASUREMENTS (en)
|
skos:prefLabel
| - STATISTICAL VERIFICATION OF THE METHOD OF EVALUATION THE SHORT TERM RADON INTEGRATED MEASUREMENTS
- STATISTICAL VERIFICATION OF THE METHOD OF EVALUATION THE SHORT TERM RADON INTEGRATED MEASUREMENTS (en)
|
skos:notation
| - RIV/61989100:27200/10:86076497!RIV11-MSM-27200___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/61989100:27200/10:86076497
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Eureqa software; symbolic regression; linear regression; verification; evaluation method; integrated measurement; indoor radon (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - MENDEL 2010, 16th International Conference on Soft Computing
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Danihelka, Pavel
- Praks, Pavel
- Dubčáková, Renáta
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open...ain/vavai/riv/wos
| |
http://linked.open.../riv/zahajeniAkce
| |
issn
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| |
https://schema.org/isbn
| |
http://localhost/t...ganizacniJednotka
| |