About: COMPARISON OF REACTIVITY OF SYNTHETIC AND BOVINE HYDROXYAPATITE IN VITRO UNDER DYNAMIC CONDITIONS     Goto   Sponge   Distinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Hydroxyapatite materials prepared by two methods: synthetic (HA-S) and bovine (HA-B) granules were exposed to a long-term in vitro test under dynamic conditions. Testing cells, filled up to one fourth (?V) of their volume with the tested material, were exposed to continuous flow of simulated body fluid (SBF) for 56 days. The objective of the experiment was to determine whether reactivity of the biomaterials (hydroxyapatites), prepared by different methods but identical in terms of their chemical and phase composition, in SBF were comparable. Analyses of the solutions proved that both materials were highly reactive from the very beginning of interaction with SBF (significant decrease of Ca2+ and (PO4)3- concentrations in the leachate). SEM/EDS images have shown that the surface of bovine HA-B was covered with a new hydroxyapatite (HAp) phase in the first two weeks of the test while synthetic HA-S was covered after two weeks of the immersion in SBF. At the end of the test, day 56, both materials were completely covered with well developed porous HAp phase in form of nano-plates. A calculation of the rate of HAp formation from the concentration of (PO4)3- ions in SBF leachates confirmed that all removed ions were consumed for the formation of the HAp phase throughout the entire testing time for bovine HA-B and only during the second half of the testing time for synthetic HA-S.
  • Hydroxyapatite materials prepared by two methods: synthetic (HA-S) and bovine (HA-B) granules were exposed to a long-term in vitro test under dynamic conditions. Testing cells, filled up to one fourth (?V) of their volume with the tested material, were exposed to continuous flow of simulated body fluid (SBF) for 56 days. The objective of the experiment was to determine whether reactivity of the biomaterials (hydroxyapatites), prepared by different methods but identical in terms of their chemical and phase composition, in SBF were comparable. Analyses of the solutions proved that both materials were highly reactive from the very beginning of interaction with SBF (significant decrease of Ca2+ and (PO4)3- concentrations in the leachate). SEM/EDS images have shown that the surface of bovine HA-B was covered with a new hydroxyapatite (HAp) phase in the first two weeks of the test while synthetic HA-S was covered after two weeks of the immersion in SBF. At the end of the test, day 56, both materials were completely covered with well developed porous HAp phase in form of nano-plates. A calculation of the rate of HAp formation from the concentration of (PO4)3- ions in SBF leachates confirmed that all removed ions were consumed for the formation of the HAp phase throughout the entire testing time for bovine HA-B and only during the second half of the testing time for synthetic HA-S. (en)
Title
  • COMPARISON OF REACTIVITY OF SYNTHETIC AND BOVINE HYDROXYAPATITE IN VITRO UNDER DYNAMIC CONDITIONS
  • COMPARISON OF REACTIVITY OF SYNTHETIC AND BOVINE HYDROXYAPATITE IN VITRO UNDER DYNAMIC CONDITIONS (en)
skos:prefLabel
  • COMPARISON OF REACTIVITY OF SYNTHETIC AND BOVINE HYDROXYAPATITE IN VITRO UNDER DYNAMIC CONDITIONS
  • COMPARISON OF REACTIVITY OF SYNTHETIC AND BOVINE HYDROXYAPATITE IN VITRO UNDER DYNAMIC CONDITIONS (en)
skos:notation
  • RIV/60461373:22310/14:43897512!RIV15-TA0-22310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(TE01020390)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 8165
http://linked.open...ai/riv/idVysledku
  • RIV/60461373:22310/14:43897512
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • SBF; in vitro test; Hydroxyapatite (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [D6D561E7FCE9]
http://linked.open...i/riv/nazevZdroje
  • Ceramics-Silikáty
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 58
http://linked.open...iv/tvurceVysledku
  • Helebrant, Aleš
  • Horkavcová, Diana
  • Kuncová, Lenka
  • Rohanová, Dana
  • Zítková, Klára
  • Zlámalová Cílová, Zuzana
issn
  • 0862-5468
number of pages
http://localhost/t...ganizacniJednotka
  • 22310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software