Attributes | Values |
---|
rdf:type
| |
Description
| - Presented paper deals with the problematic of easy on-field, fast and low-cost monitoring of species or elements contained in biological samples and/or environment. For this purpose the screen-printed thick-film electrochemical sensor with embedded micropotentiostat have been designed and used for determination of cadmium and led in aqueous solution contrary to toxic mercury drop electrode and big scale measurement devices that are usually used for such analyses in laboratories. The micropotentiostat is controlled by a personal computer. It provides the same measurement methods like big commercial laboratory devices (CV, DPV, etc.). The advantage of such microsystem is that the noise ratio caused by leads is reduced because the low signal from the electrodes to the micropotentiostat is not transmitted through additional wires or connectors. Presented microsystem has been used for detection of Cd(II) and Pb(II) ions in this work. We were able to determine units of uM of the metals.
- Presented paper deals with the problematic of easy on-field, fast and low-cost monitoring of species or elements contained in biological samples and/or environment. For this purpose the screen-printed thick-film electrochemical sensor with embedded micropotentiostat have been designed and used for determination of cadmium and led in aqueous solution contrary to toxic mercury drop electrode and big scale measurement devices that are usually used for such analyses in laboratories. The micropotentiostat is controlled by a personal computer. It provides the same measurement methods like big commercial laboratory devices (CV, DPV, etc.). The advantage of such microsystem is that the noise ratio caused by leads is reduced because the low signal from the electrodes to the micropotentiostat is not transmitted through additional wires or connectors. Presented microsystem has been used for detection of Cd(II) and Pb(II) ions in this work. We were able to determine units of uM of the metals. (en)
|
Title
| - Embedded micropotetiostat on screen-printed sensor for heavy metals analysis
- Embedded micropotetiostat on screen-printed sensor for heavy metals analysis (en)
|
skos:prefLabel
| - Embedded micropotetiostat on screen-printed sensor for heavy metals analysis
- Embedded micropotetiostat on screen-printed sensor for heavy metals analysis (en)
|
skos:notation
| - RIV/00216305:26220/08:PU78018!RIV10-MSM-26220___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GA102/08/1546), Z(MSM0021630503)
|
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26220/08:PU78018
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - micropotentiostat, thick-film sensor, cadmium, lead (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - Proceedings of the conference Eurosensors XXII
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Adam, Vojtěch
- Fujcik, Lukáš
- Hubálek, Jaromír
- Kizek, René
- Kuchta, Radek
- Prášek, Jan
- Prokop, Roman
- Adámek, Martin
- Šílený, Jan
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
http://linked.open...n/vavai/riv/zamer
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| - VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA)
|
https://schema.org/isbn
| |
http://localhost/t...ganizacniJednotka
| |