About: Low-frequency centroid-moment-tensor inversion from superconducting-gravimeter data: The effect of seismic attenuation     Goto   Sponge   Distinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • After the 2010 Maule and 2011 Tohoku earthquakes the spheroidal modes up to 1 mHz were clearly registered by the Global Geodynamic Project (GGP) network of superconducting gravimeters (SG). Fundamental parameters in synthetic calculations of the signals are the quality factors of the modes. We study the role of their uncertainties in the centroid-moment-tensor (CMT) inversions. First, we have inverted the SG data from selected GGP stations to jointly determine the quality factors of these normal modes and the three low-frequency CMT components, M-rr, (K-theta theta - M-phi phi)/2 and M-theta phi, that generate the observed SG signal. We have used several-days-long records to minimize the trade-off between the quality factors and the CMT but it was not eliminated completely. We have also inverted each record separately to get error estimates of the obtained parameters. Consequently, we have employed the GGP records of 60-h lengths for several published modal-quality-factor sets and inverted only the same three CMT components. The obtained CMT tensors are close to the solution from the joint Q-CMT inversion of longer records and resulting variability of the CMT components is smaller than differences among routine agency solutions. Reliable low-frequency CMT components can thus be obtained for any quality factors from the studied sets. (C) 2014 Elsevier B.V. All rights reserved.
  • After the 2010 Maule and 2011 Tohoku earthquakes the spheroidal modes up to 1 mHz were clearly registered by the Global Geodynamic Project (GGP) network of superconducting gravimeters (SG). Fundamental parameters in synthetic calculations of the signals are the quality factors of the modes. We study the role of their uncertainties in the centroid-moment-tensor (CMT) inversions. First, we have inverted the SG data from selected GGP stations to jointly determine the quality factors of these normal modes and the three low-frequency CMT components, M-rr, (K-theta theta - M-phi phi)/2 and M-theta phi, that generate the observed SG signal. We have used several-days-long records to minimize the trade-off between the quality factors and the CMT but it was not eliminated completely. We have also inverted each record separately to get error estimates of the obtained parameters. Consequently, we have employed the GGP records of 60-h lengths for several published modal-quality-factor sets and inverted only the same three CMT components. The obtained CMT tensors are close to the solution from the joint Q-CMT inversion of longer records and resulting variability of the CMT components is smaller than differences among routine agency solutions. Reliable low-frequency CMT components can thus be obtained for any quality factors from the studied sets. (C) 2014 Elsevier B.V. All rights reserved. (en)
Title
  • Low-frequency centroid-moment-tensor inversion from superconducting-gravimeter data: The effect of seismic attenuation
  • Low-frequency centroid-moment-tensor inversion from superconducting-gravimeter data: The effect of seismic attenuation (en)
skos:prefLabel
  • Low-frequency centroid-moment-tensor inversion from superconducting-gravimeter data: The effect of seismic attenuation
  • Low-frequency centroid-moment-tensor inversion from superconducting-gravimeter data: The effect of seismic attenuation (en)
skos:notation
  • RIV/00216208:11320/14:10283557!RIV15-MSM-11320___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(LM2010008)
http://linked.open...iv/cisloPeriodika
  • -
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 26703
http://linked.open...ai/riv/idVysledku
  • RIV/00216208:11320/14:10283557
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • CMT inversion; Quality factors; Superconducting-gravimeter data; Normal modes (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [6345FF366EBE]
http://linked.open...i/riv/nazevZdroje
  • Physics of the Earth and Planetary Interiors
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 235
http://linked.open...iv/tvurceVysledku
  • Matyska, Ctirad
  • Zábranová, Eliška
http://linked.open...ain/vavai/riv/wos
  • 000343020200003
issn
  • 0031-9201
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.pepi.2014.06.013
http://localhost/t...ganizacniJednotka
  • 11320
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software