Attributes | Values |
---|
rdf:type
| |
Description
| - According to EN ISO 7730 the estimation of operative temperature and RTA is prescribed; it has been measured by Indoor Climate Analyzer of Bruel and Kjaer. It was proved that a new instrument, globe stereothermometer, can be applied for this purpose. It is a globe of 15 cm in diameter divided into 6 segments; the surface temperature of each segment is called stereotemperature. The mean value of all six stereotemperatures equals to globe temperature for low velocities being equal to operative temperature.
- According to EN ISO 7730 the estimation of operative temperature and RTA is prescribed; it has been measured by Indoor Climate Analyzer of Bruel and Kjaer. It was proved that a new instrument, globe stereothermometer, can be applied for this purpose. It is a globe of 15 cm in diameter divided into 6 segments; the surface temperature of each segment is called stereotemperature. The mean value of all six stereotemperatures equals to globe temperature for low velocities being equal to operative temperature. (en)
|
Title
| - Globe stereothermometer : a new instrument for measurement and evaluation of irregularradiant-convective load
- Globe stereothermometer : a new instrument for measurement and evaluation of irregularradiant-convective load (en)
|
skos:prefLabel
| - Globe stereothermometer : a new instrument for measurement and evaluation of irregularradiant-convective load
- Globe stereothermometer : a new instrument for measurement and evaluation of irregularradiant-convective load (en)
|
skos:notation
| - RIV/00025950:_____/10:00000020!RIV11-MPS-00025950
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00025950:_____/10:00000020
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - operative temperature; radiant temperature asymmetry; local comfort criteria; thermal comfort (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - AHFE International : 3rd International Conference on Applied Human Factors and Ergonomics (AHFE)
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Jokl, Miloslav
- Tomášková, Hana
- Jirák, Zdeněk
- Malý, Stanislav
- Bernatíková, Šárka
- Oleksiaková, Zuzana
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
http://linked.open...n/vavai/riv/zamer
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| |
https://schema.org/isbn
| |