Attributes | Values |
---|
rdf:type
| |
rdfs:seeAlso
| |
Description
| - A submitted project deals with the aerodynamics research of advanced axial - flow fans with the increased flow rates, effiiency and pressure increment for power and environmental plants. The design of three variants of new stages with hub/tip ratio of 0,6 is assumed. Pressure coefficient will be 0,90 - 0,95 . The results of flow simulations in axial- flow stages will be applied in design considerations. It is necessary to investigate the 3D flow in the inlet suction chamber for the efficiency increase of axial fans. New aial - flow stages will be examined on model test rig with external diameter of 600 mm. 5-hole conical pressure probes will be used in the experimental investigation of 3D folw in considered axial- flow stages. For this reason design assumption can be verified. In one stage variant stator vanes will be shaped from flat plate in order to decrease the fan production costs. (en)
- Výzkum osového ventilátoru pro energetická a ekologická zařízení se zvýšenou hltností , účinností a přírustkem tlaku. Předpokládá se aerodynamický návrh tří variant nových lopatkových stupňů s nábojovým poměrem 0,6 a tlakovým součinitelem 0,90 - 0,95. Při tom budou použity nejmodernější teoretické metody včetně numerické simulace proudění.Bude také snaha snížit energetické ztráty proudění v sací komoře. Navržené stupně budou budou experimentálně ověřeny na zkušební trati s půměrem 600 mm. U jedné varianty stupně budou aplikovány statorové lopatky vytvořené z plechu. Na základě teoretického rozboru výsledků experimentu může být sestavena nová ventilátorová řada mající výkonové parametry na mezinárodní úrovni.
|
Title
| - Advanced fans for power and environmental arrangements (en)
- Ventilátory s progresivními parametry pro energetická a ekologická zařízení.
|
skos:notation
| |
http://linked.open...avai/cep/aktivita
| |
http://linked.open...kovaStatniPodpora
| |
http://linked.open...ep/celkoveNaklady
| |
http://linked.open...datumDodatniDoRIV
| |
http://linked.open...i/cep/druhSouteze
| |
http://linked.open...ep/duvernostUdaju
| |
http://linked.open.../cep/fazeProjektu
| |
http://linked.open...ai/cep/hlavniObor
| |
http://linked.open...hodnoceniProjektu
| |
http://linked.open...vai/cep/kategorie
| |
http://linked.open.../cep/klicovaSlova
| - Axial flow fan; decrease of energy consumption; environmental arrangement, coal fired power (en)
|
http://linked.open...ep/partnetrHlavni
| |
http://linked.open...inujicichPrijemcu
| |
http://linked.open...cep/pocetPrijemcu
| |
http://linked.open...ocetSpoluPrijemcu
| |
http://linked.open.../pocetVysledkuRIV
| |
http://linked.open...enychVysledkuVRIV
| |
http://linked.open...lneniVMinulemRoce
| |
http://linked.open.../prideleniPodpory
| |
http://linked.open...iciPoslednihoRoku
| |
http://linked.open...atUdajeProjZameru
| |
http://linked.open.../vavai/cep/soutez
| |
http://linked.open...usZobrazovaneFaze
| |
http://linked.open...ai/cep/typPojektu
| |
http://linked.open...ep/ukonceniReseni
| |
http://linked.open.../cep/vedlejsiObor
| |
http://linked.open...ep/zahajeniReseni
| |
http://linked.open...jektu+dodavatelem
| - Navrženy 4 vysokotlaké osové stupně pro moderní ventilátory na uhelných elektrárnách s využitím nejnovějších výpočtových metod. Nové stupně byly experimentálně ověřeny. Vytvořena nová ventilátorová řada. (cs)
- Four high pressure axial stages were designed for advanced fans in coal power stations with the use of new computational methods. New stages were experimentally verified. New fan series was established. (en)
|
http://linked.open...tniCyklusProjektu
| |
http://linked.open.../cep/klicoveSlovo
| - decrease of energy consumption
- environmental arrangement
- Axial flow fan
|
is http://linked.open...vavai/riv/projekt
of | |
is http://linked.open...vavai/cep/projekt
of | |