About: Piezoelectric sensors for biological agent detection: optimization of signal to noise ratio     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Projekt, within Data Space : linked.opendata.cz:8890 associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The main goals are the following: to design the resonator based on the piezoceramics working in the frequency range up to 10 MHz and ZnO crystal resonator up to 100 MHz. Electrical and noise parameters of the piezosensor and ZnO crystal without antigen layer will be analyzed and mathematical modeling will be used to estimate eigen-functions and eigen-frequencies of both resonators. To improve the signal to noise ratio, detectivity, responsivity and noise equivalent power of both sensors will be experimentally determined. We will concentrate on the optimization of antigen layer and noise measurement error reduction by using a differential measurement set-up. (en)
  • Cílem jsou návrhy senzorů pro frekvenční pásma od 10 MHz do 100 MHz. Senzory jsou tvořeny piezokeramickým monolitickým rezonátorem (10 MHz) a rezonátorem založeným na tenké vrstvě piezokeramiky (100MHz). Šumové a elektrické vlastnosti piezo-senzorů bez antigenové vrstvy budou analyzovány a následně bude vytvořen matematický model popisující tyto vlastnosti. Na základě simulací bude proveden odhad jejich vlastních frekvencí a přenosových funkcí obou senzorů. K dosažení zlepšení poměru signál/šum je nutné provést měření citlivosti, rozlišovací schopnosti a ekvivalentního šumového výkonu u obou senzorů. Naším úkolem je konstrukce senzorů na bázi piezokeramiky, a to monolitických rezonátorů a rezonátorů připravených tlustovrstvovou technologií. Tato problematika je součástí grantu GAČR 102/06/0866 „Nelineární elektroultrazvuková spektroskopie pevných látek“. Dalším úkolem je najít optimální parametry antigenové vrstvy a vypracovat metodiku diferenciálního měření za účelem zvýšení citlivosti.
Title
  • Piezoelectric sensors for biological agent detection: optimization of signal to noise ratio (en)
  • Piezoelektrické senzory pro detekci biologických látek: optimalizace poměru signál/šum
skos:notation
  • ME 896
http://linked.open...avai/cep/aktivita
http://linked.open...kovaStatniPodpora
http://linked.open...ep/celkoveNaklady
http://linked.open...datumDodatniDoRIV
http://linked.open...i/cep/druhSouteze
http://linked.open...ep/duvernostUdaju
http://linked.open.../cep/fazeProjektu
http://linked.open...ai/cep/hlavniObor
http://linked.open...hodnoceniProjektu
http://linked.open...vai/cep/kategorie
http://linked.open.../cep/klicovaSlova
  • Antigen layer; Bio-Sensor; Signal to Noise Ratio; Piezoceramic Resonator (en)
http://linked.open...ep/partnetrHlavni
http://linked.open...inujicichPrijemcu
http://linked.open...cep/pocetPrijemcu
http://linked.open...ocetSpoluPrijemcu
http://linked.open.../pocetVysledkuRIV
http://linked.open...enychVysledkuVRIV
http://linked.open...lneniVMinulemRoce
http://linked.open.../prideleniPodpory
http://linked.open...iciPoslednihoRoku
http://linked.open...atUdajeProjZameru
http://linked.open.../vavai/cep/soutez
http://linked.open...usZobrazovaneFaze
http://linked.open...ai/cep/typPojektu
http://linked.open...ep/ukonceniReseni
http://linked.open...ep/zahajeniReseni
http://linked.open...jektu+dodavatelem
  • Detektivita QCM senzoru je určena g-r a 1/f šumem adsorpce a desorpce molekul analyzovaného plynu. Na základě Kolmogorovovy rovnice byl odvozen model výměny molekul na aktivní vrstvě. Limitní hodnota detekované hmotnosti je určena šumem 1/f a závisí na geometrii a součiniteli kvality senzoru. (cs)
  • %22QCM sensor detectivity is determined by g-r and 1/f noise of analyzed gas molecules adsorption and desorption. The model of the molecules exchange on the active layer was derived on the base of Kolmogorov equation. The limit value of detected mass is determined by 1/f noise and depends on the sensor geometry and quality factor. %22 (en)
http://linked.open...tniCyklusProjektu
http://linked.open.../cep/klicoveSlovo
  • Bio-Sensor
  • Signal to Noise Ratio
  • Antigen layer
is http://linked.open...vavai/cep/projekt of
Faceted Search & Find service v1.16.121 as of Mar 31 2025


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3240 as of Mar 31 2025, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 39 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software